Chapter 6: Programming Information A794 Owner’s Guide
December 1999126
Select Standard Mode
ASCII ESC S
Hexadecimal 1B 53
Decimal 27 83
Switches from Page Mode to Standard Mode. In switching from Page Mode to Standard
Mode, data buffered in Page Mode are cleared, the printing area set by Set Print Area in
Page Mode (1B 57) is initialized and the print position is set to the beginning of the line.
This command switches the settings for the following commands (the values for these
commands can be set independently in Standard Mode and Page Mode) to those for
Standard Mode:
Set Right-Side Character Spacing (1B 20)
Select 1/6 Inch Line Spacing (1B 32)
Set Line Spacing (1B 33)
Standard Mode is automatically selected when power is turned on, the printer is reset,
or the Initialize Printer command (1B 40) is used.
Exceptions
This command is effective only in Page Mode.
Select Print Direction in Page Mode
ASCII ESC T n
Hexadecimal 1B 54 n
Decimal 27 84 n
Value of n: Start position
0 = Upper left corner proceeding across page to the right (A)
1 = Lower left corner proceeding up the page (B)
2 = Lower right corner proceeding across page to the left
(upside down) (C)
3 = Upper right corner proceeding down page (D)
A
D
B
Default: 0